Technical specification | External setting ON/OFF the unit Thanks to the installation of an 11-poles relay (K98) and the use of a control voltage, the unit can be externally set on and off. Two different types of relays can be used for the setting on and off of the unit: - relay 24 V DC - relay 230 V AC The contacts of the relay K98 and of the ON/OFF switch (S1) of the unit are wired parallel. If the unit must be turned on and off externally, the green switch ON/OFF on the unit (0 – 1 switch) must be always on position OFF. Otherwise, the unit cannot be turned off externally. The coil of the 11-poles relay K98 for the external command is wired on 2 terminals (No. 200, 201) |