Technical specification ET Turbo-Lux 3 DN 100 450 GPM Description: Turbo-Lux 3 workings Measuring principle: Measuring orifice as effective pressure transmitter with bypass flow meter Flow direction: arbitrary, taking into account the direction of the arrow Installation position: any Measurement accuracy Measurement deviation: ± 2.0% of the measurement range end value (FM) ± 5.0% of measured value (LPCB) ± 2.5% of the end measurement range value (VdS) process conditions Nominal size: 4"/DN 100 (ø 114.3 mm) grooved Pump rating: 450 USgpm Inlet and outlet route: 5 x D and 2 x D Display range: 180 — 900 usGPM 680 - 3400 lpm Installation length: 100 mm (+0.0 mm/ -3.0 mm) operating conditions Medium: water Operating temperature: +4 to +50 °C max. operating pressure: FM 500 psi (34.5 bar) LPCB/ VdS PN16 (232 psi) Constructive structure Case tube: stainless steel Effective pressure sampling tube: brass Floater: stainless steel Bypass cover: stainless steel Filter screen: stainless steel Filter screen: stainless steel Seal: NBR FM Certificates/Approvals LPCB VdS Measurement accuracy certificate (bypass meter): with State Item no.: 90261081 Country of origin: Federal Republic of Germany AL: N ECCN: N PREF-J: ALL