Prices  SST2200A  Dynalco  United States

BRAND Dynalco
Product SST2200A
Description Transducer with sensor
Internal code IMP4876297
Technical specification Proportional outputs of either 4–20 mA (standard), 0–5 Vdc, or 0–10 Vdc are fieldselectable. Standard 0-1 mAdc meter output included Models available with up to four alarm setpoints Field-selectable frequency range Field-adjustable sensitivity control Field-programmable for many types of sensors, including contact closure input Repeater output drives counters and self-powered digital tachometers such as Dynalco's SPD-100 and SPD-700 Regulated 14 Vdc output powers active pickups (e.g. M910), accessories, and digital meters such as DPM-105 or MTH-103D, and the 12 Vdc versions of the internally lighted SPD-100L and LST-100L Alarms are field-configurable for DPDT (SST-2400 A or -H only), overspeed,underspeed, energize, de-energize, latch, auto-reset Integral VERIFY, requires external meter. Permits viewing and setting of setpoint value without actuating the relays Input Frequency: Full-scale values from 0–0.1Hz (6 pulses per minute) to 0–50,000 Hz Function: Converts frequency input (speed, rate) into linear proportional dc output. Provides alarm setpoints for over- and underspeed control and for sequential, startup, and shutdown switching Applications: Includes engines, machines, I/P drivers, instrumentation, process control, recording, measurement Signal Sources: Includes magnetic pickups, ac generators, contact closures, photocells Output Range Capability: Current source up to 50 mAdc output always included Alarm Setpoints: Available with two or four relays. Also available with no relays if only proportional outputs are required.