Prices  QS8M100  Elster  United States

BRAND Elster
Product QS8M100
Internal code IMP4885596
Custom code 90289090
Technical specification Q.SONIC MAX DN100 (4") Configured model number: YQS8M100-AC030DAEAAAB-BYAABAAAAA-AAD0048AAA0600040048-AAA0BAAAAACABA08000AAAA-000019001000 Special features: Yes Standard special options: None Line # 1 for instructions: PAINT COLOR Line # 2 for instructions: RAL 7035 (LIGHT GREY) Line # 3 for instructions: TAG NUMBER Line # 4 for instructions: 902-05-FT-001 Line # 5 for instructions: USM-2023-294 Material number: QS8M100 Customer version: No Pressure level: Class 300 (hr) Internal diameter: 97 mm (3.82 in) Flange connection: 102.3 mm (4.03 in) Case material: ASTM A350 LF2 (3.1 material) Std Design Code Case: ASME B31.8 (0.6) (Std) Design Code Flange: ASME B16.5 (RF) (Std) Pressure connection: 1x 1/2inch NPT (unplugged) Flow direction: right - left Paint color: Other RAL color Coating system: C3 in accordance with ISO 12944-2 (standard) Internal coating: Std Transducer mounts: 304 stainless steel with PMI Meter cover: 304 stainless steel Metrological approval: AGA9 compliant Explosion protection standard: ATEX (hours) Duration of tightness test: 1.1xPD 5 min (h) Duration of strength test: maximum pressure 30 min System of units: Metric units Minimum design temperature: -40 °C Maximum design temperature: 85°C (185°F) Maximum design pressure [barg]: 0048 Pressure tightness test [barg 0052 Pressure strength test [bar 0077 Storage temperature: standard (-20degC #60DegC) Minimum gas temperature °C: -40 °C Maximum gas temperature °C: 060 Minimum meter pressure [barg]: 004 Maximum counter pressure [barg]: 0048 SPU material: aluminum (Std) Cable screw thread: M20x1 (Std) Cable screw material: brass (hours) Number of cable connections: 0 cable connections (hours) Network connection: Ethernet range extender intrnl Internal temperature sensor: Internal temperature sensor Internal pressure sensor: None (standard) Frequency output 2: frequency Dig (OC) /Analog (AO) Output 1 OC: Partial Failure (Std) Dig (OC) /Analog (AO) output 2 OC: flow direction Frequency output: Qline (Std) Signal: SB Maximum frequency: 3000 Hz (hours) Counter pulses/Cp factor: 08000 COM1 serial output: ModBus/9600/RS485 (Std) COM2 serial output: ModBus/9600/RS485 (Std) Reynolds Correction: Static Correction Operating language: English Qmin: 000019 Qmax: 001000 Qt: 000100 Minimal Ambient temperature: -40 °C (-40°F) (hours) Maximum Ambient temperature: 60°C (140°F) (hours) Product group: Natural gas (Std) Counter length MM: 0400 Meter volume L: 003 Weight KG: 0080 External high pressure test: None (standard) Customer-specific test plan: None (standard) Digital copy of MRB: None (standard) Packing: ISPM standard packing Rectifier: None (standard) Configuration check: All entries completed Table 1 and 2 Key: -AC030DAEAAAB-BYAABAAAAA Table 3 Key: -AAD0048AAA0600040048 Table 4 to 5 Key: -AAA0BAA-AAACABA08000AAAA Table 6 Key: 000019001000000100AAA0400003 Table 7 Key: 0080-AAAAA Int. extender No of Cable Glands QS8M100 #300

default.send_request_amp_Group2