Prices  77029DCEx_G (NLSW45-3 Ex 24 V DC)  Seikom  United States

BRAND Seikom
Product 77029DCEx_G (NLSW45-3 Ex 24 V DC)
Description evaluation unit
Internal code IMP1864093
Weight 0.35
Custom code 90268020
Technical specification Evaluation unit for control cabinet installation (separate sensor sold separately) Operating voltage: 24 V DC, alternatively available with 24 V AC, 230 V AC operating voltage Measurement range: 0.1 m/s... 20 m/s Media temperature range: 0°C... 60°C Signal output: relay, changeover contact Model tested by TÜV Nord in accordance with DIN EN 61010-1 2011-07 Includes 2 x Zener barriers with ATEX approval (Gg) The device is in conjunction with provided Zener barriers and the separately available sensor F3. *Ex (available in 50 mm, 130 mm, 165 mm, 300 mm immersion depths) suitable for Flow monitoring of gaseous media in zone 2 and temperature class T4. In addition Are the requirements for simple electrical equipment in intrinsically safe circuits in the ATEX zone 1 complies with EN 60079-11. The nlsw45-3ex airflow monitor and Zener barriers must be installed and operated outside the potentially explosive area.

default.send_request_amp_Group2