Prices  PR-SPA-EX-NWT / 901210421000001  Ephy Mess  United States

BRAND Ephy Mess
Product PR-SPA-EX-NWT / 901210421000001
Description Temperature Element, Thermocouple
Internal code IMP4975394
Custom code 90259000
Technical specification PR-SPA-EX-NWT iBEXu 14 ATEX 1281U IECEx IBE 14.0058U INMETRO TÜV_20.0889 U (II 2G) Ex ia IIC Gb (II 2G) Ex eb IIC Gb Flexible slot thermometer NWT-M-OK-AK-ESH 1Pt100, 3-wire circuit Class A ±0.15°C at 0°C in accordance with DIN EN 60751 PTFE, dimensions: 2.5+0.5/0x7+0.5/0x50±2mm Supply line: shielded hose cable 1x [3xAWG 24/7-Cu-silver-plated/PTFE/PTFE peeling film/Cu-silver-plated/PTFE, Kl=6000mm, diameter: 3.3 mm] WH (RD/RD/WH), Measurement range: -50°C... +180°C Ambient temperature: -50°C... +180°C Dielectric strength: 2.5 kV AC. 50 Hz/1min. Dielectric strength shield against outer jacket: 0.5 kV AC. 50 Hz/1min. Free range: 30mm Shield not placed on the sensor housing Shield removed on the connection side Calibration point (s): 0/70/180 °C Country of origin: Germany AL: N/ECCN: N/HS/Custom Tariff: 90259000 Net weight: 153.95 g/piece The user manual is delivered in German or English. ATTENTION: Please ensure through your ATEX representative that the above article meet your construction requirements if the items only have an ATEX partial certificate (U) and not an ATEX full certificate (X). EPHYMESS is unable to perform this check.

default.send_request_amp_Group2