Prices  PCH 1026-CHF8830  PCH Engineering  United States

BRAND PCH Engineering
Product PCH 1026-CHF8830
Description 2 channel wind turbine monitoring system
Internal code IMP2294508
Weight 1
Technical specification Parameter setting according to specifications 2 vibration sensors, intern  - Measuring direction: A and B horizontal, longitudinal and transverse direction to the mounting surface - Measuring range: 1- 100 m / s², 0.1-10 g - mean value, 0.010 to 100 sec. Resolution 0.01 sec. - Max. Tip, or tip tip - rise time 1- 100 msec., Fall time 0.1 - 100 sec. - 4 alarm relays, freely selectable, pre- and main alarm, - Response delay, adjustable 0.1 to 100 sec. - Aluminum housing, for wall mounting, IP 67 - Connection via plug-in terminals and SUB-D plug for interface - RS 232 interface, PC connection for configuration - RS 485 interface, connection to other PCH 1026 systems, - Supply voltage, 20 - 30 V DC - Incl. Connection cable, length 2 meters - PCH 1012 software, including configuration of the measurement task

default.send_request_amp_Group2