Technical specification PrimaX P, M25, hydrogen (4.0), H+R - Explosion-proof EX transmitter Junction housing (Exd) - Powder-coated aluminum housing - ATEX approval: Gas: II 2G Ex d ia [ia] IIC T4 Gb Dust: II 2D Ex tb ia [ia] IIIC T130°C Db - Type examination certificate numbers: BVS 10 ATEX E009 X, IECEx BVS 10.0063X N1 - Safety level: SIL2 - Housing protection class: IP 66 - Measuring principle: catalytic - Measurement range: 0-100% LEL hydrogen (IEC) - Display: LCD and 3 x status LED - Output: 4-20 mA - Relay contacts for alarm and fault (1A/30 VDC changeover contact) and HART communication - Cell temperature range: -40°C to +70°C - Power consumption: 24 VDC/3 W typical - Dimensions: 220 x 162 x 100 mm (H x W x D) - Includes Exd cable fitting, nickel-plated brass, M25 x 1.5 mm, for Ø 9-16 mm - Includes splash protection and calibration cap