BRAND | Bieler Lang |
Product | 12.600764.3 / HC 150 |
Description | gas sensor ExDetector HC 150 |
Internal code | IMP297575 |
Weight | 0.6 |
Technical specification | Gas sensor type: ExDetector for use in hazardous areas of zone 2 Housing/electronics: II 3G Ex nA de IIC T4 Sensor head: II 2G EEx d IIC T4 PTB 00 ATEX 1076U EG-type examination certificate: BAM 16 ATEX 0801X SIL-1 capable Measurement principle: heat effect Sample gas: Expl. gases and vapours Measuring range: 0 - 100% LEL Measurement signal: 4 - 20 mA Temperature: -20 to +55°C Supply: 18V DC Degree of protection: IP 54 Design: aluminum housing, stainless steel sensor one-man calibration, direct adjustment on the probe |