BRAND | Labom |
Product | CV3110 1817497/10/002 |
Internal code | IMP4308737 |
Custom code | 90262020 |
Technical specification | MZ1100-B901-W1201 CV3110-A1059-F80-H2100-M1-N10-T30-K1085 BH4200-A90-T2-W4026 DL3230-HY06-A4007-L23-T64-W4035-W1020-W1102-W1223 Order Code: MZ1100 COMBIBAR PRESSURE MEASURING SYSTEM B901 drawing no.: see below process connection left (9.00 o`clock) drawing PD-WV-00322-k INSPECTION CERTIFICATE DIN EN 10204 3.1 calibration certificate with 5 measuring points W1201 PRESSURE TRANSMITTER PASCAL CV, for diaphragm seal operation, hygienic acc. to data sheet D4-017/22 CV3110 A1 pressure sensor: piezoresistive for gauge pressure 059 nominal range: 0...16 bar, overload limit 60 bar measuring range setting: turndown 5:1 accuracy: <= 0.15% of measuring span (linearity, hysteresis and repeatability) F80 measuring range: setting see below lower range value: - 1,000 upper range value: + 5,000 unit: bar H21 output signal: 4...20 mA with HART function module 0 setting damping: 0.0 sec. (standard)0 setting alarm state: < 3.6 mA (standard) M1 display module: without screw cap closed, without window N10 switching module: without case: hygienic housing design with screw cap material: stainless steel degree of protection: IP 66 T30 electrical connection: circular connector M12x1 (4 pin) K1085 design standard process temperature 0...+125 °C, short term up to +140 °C, 1 h BOURDON TUBE PRESSURE GAUGE with diaphragm seal connection, chemical design acc. to data sheet D2-029 BH4 2 case: NS 100 00 case design: IP 65, process connection bottom A accuracy: class 1.0 per EN 837-1 90 nominal range: -1...5 bar pointer: with micro adjustment T2 marking: on scale, see below red mark at +3 bar W4026 ADDITIONAL DESIGN: positioning process connection 9 o`clock DL DIAPHRAGM SEAL for food / pharmaceutical / biotechnology design with clamp connection see data sheet D5-026 3 process connection: per DIN 32676 model C (Tri-Clamp) for pipes per ASME BPE, DN 1 1/2" / PN 25 230 hygienic design per EHEDG Doc.8 and ASME BPE SF1: surface roughness (wetted parts) - turned parts Ra <= 0.51 µm - diaphragm Ra <= 0.38 µm - weld seam Ra <= 0.76 µm HY06 A400 connection of meas. instrument directly welded 7 material wetted parts: stainless steel mat.-no. 1.4435 (316L) system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered L23 T64 temperature, media: 0...+140 °C W4035 ADDITIONAL DESIGN: wetted parts electropolished Components marked acc. to material inspection certificate per EN 10204-3.1, wetted parts W1020 TEST REPORT per DIN EN 10204 2.2 as per customers specification, see below W1102 for electro polishing INSPECTION CERTIFICATE DIN EN 10204 3.1 roughness height rating Ra W1223 |
default.send_request_amp_Group2