Prices  CI4103 / CI4103-A1053-F2-H21-M21.1-Y12-T30-K1010-X4  Labom  United States

BRAND Labom
Product CI4103 / CI4103-A1053-F2-H21-M21.1-Y12-T30-K1010-X4
Description PRESSURE TRANSMITTER PASCAL
Internal code IMP4609567
Custom code 90262020
Technical specification PRESSURE TRANSMITTER PASCAL Ci4 with threaded connection process connection back see data sheet D4-016-1 CI4103 nominal range: 0...1 bar, Turndown max. 100:1, overload limit 3 bar; sensor type piezoresistiv A1053 accuracy: <= 0.10% from adjusted measuring span (Lin./Hys./Rep., up to Turndown <=5:1 no changes) parameterizing: see belowF2 device ID: LABOM PASCAL Ci4 lower range value: 0 upper range value: + 10,0000 pressure unit: mH2O unit of sensor temperature:: °C damping: 0.0 s display mode: four values principle value: pressure output function: linear residual current: low < 3,6 mA HART address 0 output signal: 4...20 mA with HARTH21 high-resolution graphic display with backlight intuitive 4-button operation, quick access to device data available languages (English, German), default setting English M21.1 material case: stainless steel mat. no. 1.4301/1.4305 (304/303)Y1 material front cover: stainless steel, window non-splittering glass2 degree of protection: IP 65 / IP 67 electrical connection: circular connector M12x1 (4 pin)T30 process connection: G 1/2 B per DIN EN 837-1K1010 material wetted parts sensor diaphragm, stainless steel mat. no. 1.4404/1.4435 (316L) - socket, stainless steel mat. no. 1.4404/1.4435 (316L) X4 software: operating software for level measurement applications

default.send_request_amp_Group2