BRAND | Labom |
Product | CC6020-A1061-H1-T130 DL5110-S1203-HY-A4007-L22-W1020 |
Internal code | IMP4175156 |
Custom code | 90262020 |
Technical specification | CC6 PRESSURE TRANSMITTER COMPACT for diaphragm seal operation 02 design: with temperature decoupler see data sheet D4-020-7 0 explosion protection: without A1 pressure sensor piezoresistive for gauge pressure 061 measuring range 0...40 bar, overload limit 100 bar measuring accuracy: linearity error incl. hysteresis < + 0.2 % f.s. accuracy of adjustment < +/- 0.2 % f.s H1 output signal: 4...20 mA, 2-wire technology T130 electrical connection: circular connector M12, IP 65, union nut of stainless steel DL5 DIAPHRAGM SEAL aseptic-design see data sheet D5-024 1 design: for pipes per DIN 11850 pipe dimension per DIN 11866 table 1 model A 10 DN 25, pipe inside-ø di 26 mm S1203 process connection: DIN 11864-3 type A, clamp connection (coupling side) HY hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 µm - diaphragm Ra <= 0.38 µm - weld seam Ra <= 0.76 µm A400 connection of meas. instrument directly welded 7 material wetted parts: stainless steel mat.-no. 1.4435 (316L) L22 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered operating temperature range -10...+140 °C W1020 Components marked acc. to material inspection certificate per EN 10204-3.1, wetted parts |