Custom code 90262020
Technical specification CC6 PRESSURE TRANSMITTER COMPACT for diaphragm seal operationCC6 01 design: standard see data sheet D4-020-5 0 explosion protection: without A1 pressure sensor piezoresistive for gauge pressure 057 measuring range 0...6 bar, overload limit 60 bar measuring accuracy: linearity error incl. hysteresis < + 0.2 % f.s. accuracy of adjustment < +/- 0.2 % f.s. H1 output signal: 4...20 mA, 2-wire technology T120 electrical connection: circular connector M12, IP 65, union nut of polyamide W2002 CALIBRATION PROTOCOL: with 5 measuring points DE2110 DIAPHRAGM SEAL for food/pharmaceutical/biotechnology, design for FERMENTER acc. to data sheet D5-028 D10 process connection: screwed plug adjustable RD 28 x 1/8, PN 40, length 40 mm A400 connection of meas. instrument directly welded 7 diaphragm material: stainless steel mat.-no. 1.4435 (316L) E7 basic body material: stainless steel mat.-no. 1.4435 (316L) gasket: without gasket L23 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered operating temperature: 0...+60 °C W5473 CUSTOMER'S SPECIFICATION: as per drawing B4-AH-00554-k-01-00.pdf - special manufacturing procedure SBV_574