Prices  CA2110-A1091-H11-T30-K2085-K147-HY-P9-W1020-W1223-W2002  Labom  United States

BRAND Labom
Product CA2110-A1091-H11-T30-K2085-K147-HY-P9-W1020-W1223-W2002
Description PRESSURE TRANSMITTER UNIVERSAL
Internal code IMP4822275
Custom code 90262020
Technical specification CA2110 PRESSURE TRANSMITTER UNIVERSAL CA for diaphragm seal operation, hygienic see data sheet D4-018-12 A1 pressure sensor: piezoresistive for gauge pressure 091 measuring range -1...9 bar, overload limit 100 bar measuring accuracy: linearity, hysteresis, repeatability <= 0.2 % of span H11 output signal: 4...20 mA, 2-wire technology T30 electrical connection: circular connector M12x1 (4 pin) K2085 design: with temperature decoupler K147 process connection: clamp connection per DIN 32676, DN 40 / PN 25 material stainless steel mat.-no. 1.4404/1.4435 (316L) system filling: Synthetic oil, free of silicon FD1, FDA listed HY hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 µm - diaphragm Ra <= 0.38 µm - weld seam Ra <= 0.76 µm P9 process temperature: see below Process temperature up to 175°C W1020 Components marked acc. to material inspection certificate per EN 10204-3.1, wetted parts W1223 INSPECTION CERTIFICATE DIN EN 10204 3.1 roughness height rating Ra W2002 CALIBRATION PROTOCOL: with 5 measuring points