Prices  244LD-CX1B1LNMHZZZ-ML1234  Foxboro (by Schneider Electric)  United States

BRAND Foxboro (by Schneider Electric)
Product 244LD-CX1B1LNMHZZZ-ML1234
Description Intelligent Buoyancy Transmitter w/Torque Tube
Internal code IMP4960428
Custom code 902610
Technical specification 244LD FUNCTION: Intelligent transmitter designed to perform measurements for liquid level, interface or density of liquids. The measurement is based on the Archimedes Buoyancy Principle. C WAFER BODY MATERIAL (Process Wetted): Hastelloy C276 - 2.4819, application from -196 °C to +400°C CONTACT TCO fo X TORQUE TUBE MATERIAL (Process Wetted): Hastelloy C276 - 2.4819 1 WAFER BODY FLANGE SIZE: DN80 B1 WAFER BODY PRESSURE RATING AND CONTACT FACE: PN40 (PN16 to PN40) B1/B1 according DIN EN 1092-1 L WAFER BODY MOUNTING DIRECTION: (Amplifier To Body Left Hand mounted N VERSION: Base VERSION LEVELSTAR - (244LD) M CABLE ENTRY M20x1.5 without cable gland H COMMUNICATION: HART® 7 and 4 to 20 mA ZZZ ELECTRICAL CLASSIFICATION: For General Purpose Areas, not explosionproof M OPTIONAL MODEL SUFFIX(ES) INCLUDED: External Push Buttons for Maintenance L OPTIONAL MODEL SUFFIX(ES) INCLUDED: Stainless Steel Label Fixed with Wire 1 OPTIONAL MODEL SUFFIX(ES) INCLUDED: EN 10204-2.1, Certificate of Compliance 2 OPTIONAL MODEL SUFFIX(ES) INCLUDED: EN 10204-2.2, Specific Test Report (Calibration) 3 OPTIONAL MODEL SUFFIX(ES) INCLUDED: EN 10204-3.1, Inspection Certificate of Pressure Retaining Parts (for wafer 4 OPTIONAL MODEL SUFFIX(ES) INCLUDED: PED 2014/68/EU additional unit verification according to module F/G 1 Calibrated Range 0 - 100 % 1 Tag No. Labeling-L LTB102 1 Lower Density 1000 kg/m³ 1 Upper Density 1.2 kg/m³

default.send_request_amp_Group2