BRAND | Gechter |
Product | VK-MX-MAXYMOS-BL-DMSPROFINET |
Description | measuring system bl |
Internal code | ONR4451390 |
Technical specification | BL/3.5" color display measuring system Table/wall enclosure for strain gauge sensor - Sensor channel Y: for strain gauges sensors, ±10 V - Sensor channel X: for potentiometer, ±10 V - Fieldbus interface: Ethernet/IP, PROFINET - Dig. IO (24V) for control and results - Ethernet TCP/IP for measurement data and remote maintenance - Evaluation elements: UNI-box, ENVELOPE, LINE, NO-PASS - 4 rating elements per curve - 16 measurement programs for 16 different parts - up to 8,000 x, y value pairs per curve - Short evaluation time - 2 real-time switching signals for X and Y threshold* - maxyMOS PC software - Info pages on NIO cause diagnosis - 24 VDC supply - plug set - without assembly *Features change with maxyMOS BL Sequencer Mode |
Press on flag images to see contact information!