Stahl

Sales Stahl in United States

Our company is the truest address of lowest price and fastest delivery in Stahl products. You can get help from our expert stuffing pattern while investigating the cost of products you needed. Stahl products, produce properly for customer's necessities, can bu used easily even if in the hardest situations. When you wish to receive tender, just let us know the information of model.

Brand products Stahl

155399

(Push button explosion-protected Type : 8602A0001-1 Enclosure material : Polyamide Seal : Standard Mounting : with threaded Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 Packed : Yes)

155476

(Rotary handle, large, raised explosion-protected Type : 8602A0724-1-ss-0 Enclosure material : Polyamide Seal : Silicone Mounting : with threaded Padlockable in : no position Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -50 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 Packed : Yes)

155785

(Label I O II)

155908

labels buttons series 8003

P/N: 160321, Type: 9170/10-12-21S

Switch amplifier digital input

160321 9170/10-12-21S

IS PAC Isolating Repeater Switching Repeater Field Circuit Ex i explosion-protected Type : 9170/10-12-21s Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Min. nominal voltage : 120 V Max. nominal voltage : 230 V Nominal current : 12 mA Number of channels : 1 Output / channel : 1 change over contact LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Dust explosion protection : II (1) D [Ex ia] IIIC For further information, see : www.r-stahl.com Web code 9170A Switching Repeater Series 9170, Field Circuit Ex i, single channel Basic function: binary / digital input Intrinsically safe input: [Ex ia] IIC Power supply: 120 ... 230 V AC Input: acc. to EN 60947-5-6 (NAMUR) Output / channel: 1 change-over contact Connection type: Screw terminals

167080: 6608/522-9611-7267

(Emergency Strip light for fluorescent lamps Type: 6608 / 5.2-9 ...-... 7 Specifications: Gas explosion: II 3 G Ex nAC II T4 dust explosion protection: II 2 DT 80 ° C test certificate: DMT 03 E 093 / ATEX e 094 x Suitable for: fluorescent lamp 2Stift, 2 x 18W reflector embodiment: symmetric wide distribution material: polyester resin surface: No coloring IP 66 ambient temperature: -20 ° C ... 40 ° C voltage: 220 V -10%. .. 254 V + 10%; 50/60 Hz cable entry: 2 x cable entry M25x1,5 1 x sealing plug M25x1,5 without bulb through wiring conductors 6 shutdown when opening the luminaire (mains voltage and battery circuit) with duration test)

168554

Repair kit 2x36W QTP8 Ers.QTIS-B Electronic Ballast + Accessories

168555

Repair kit 2x18W QTP8 QTISElektronisches Ers. Ballast + Accessories

1739084219

Control Pendant selection STH 6102-009

201386 8579/31-506

Switch socket 3P+N+PE 63A, 200/346-240/415V, 50+60Hz, red CCT No.: 85366990 DE Net weigth: 7,800 KG

201389 (TYPE : 8579/31-406)

Switch socket explosion-protected

201404 8146/5-V37-302-50-0050 SPARE OF TYPE : 8537/2-302-7000; 8537/2-702-7000

(Safety Switches 16 A explosion-protected Rated operational voltage AC : 400 V Rated operational current : 16 A Enclosure material : Polyester resin glass fibre-reinforced Detailed number of poles : 3 P Auxiliary contact NC : without Auxiliary contact NO : 1 NO lagging Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex de IIC T6 Gb Dust explosion protection : II 2 D Ex tb IIIC 80 °C Db Min. ambient temperature : -40 °C Max. ambient temperature : +51 °C Special conditions for extended ambient temperature, see operating instructions: Extended min. ambient temp. : -40 °C Extended max. ambient temp. : +69 °C Type of protection (IP) : IP66 Colour of handle : standard black Cable gland : 2 x M25 Ø 7 ... 17 mm 1 x M20 Ø 6 ... 13 mm Connection cross-section : 2,5 ... 6 mm2 Connection cross-section aux.: 1,5 ... 4 mm2 finely-stranded 1,5 ... 6 mm2 solid CCT No.: 85365080 DE Net weigth: 1,590 KG)

201404 8146/5-V37-302-50-0050 SPARE OF TYPE : 8537/2-302-7000; 8537/2-702-7000

(Safety Switches 16 A explosion-protected Rated operational voltage AC : 400 V Rated operational current : 16 A Enclosure material : Polyester resin glass fibre-reinforced Detailed number of poles : 3 P Auxiliary contact NC : without Auxiliary contact NO : 1 NO lagging Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex de IIC T6 Gb Dust explosion protection : II 2 D Ex tb IIIC 80 °C Db Min. ambient temperature : -40 °C Max. ambient temperature : +51 °C Special conditions for extended ambient temperature, see operating instructions: Extended min. ambient temp. : -40 °C Extended max. ambient temp. : +69 °C Type of protection (IP) : IP66 Colour of handle : standard black Cable gland : 2 x M25 Ø 7 ... 17 mm 1 x M20 Ø 6 ... 13 mm Connection cross-section : 2,5 ... 6 mm2 Connection cross-section aux.: 1,5 ... 4 mm2 finely-stranded 1,5 ... 6 mm2 solid CCT No.: 85365080 DE Net weigth: 1,590 KG)

203478

6141/61-16 Hand lamp with LED Hand Lamp Series 6141/6, explosion protected Rated data: 3 V Batteries: Hand lamps are supplied with batteries. For other battery types see operating instructions For use in: Zones 1 & 2, 21 & 22

203970

Fibre optic top piece

204142

Belt bag

205308

YO3/ISC/T4 ATX YO3 Hupe Ex i ATEX, T4

205315

YO5/ISC/T6 ATX YO5 Hupe Ex i ATEX, T6

205336

MCP / PB / SP / Ex / A + B + C + D / EU / R / LED / D / T push-button manual call, 12-50VDC /

211124

Batterie 6148 6V 4,5Ah replacement set

212333

Diffusing lens clear accessories

224398 8040/114-O2MN1-UL

Command and Meldegeraet

6000/521-8011-3130

Lighting with 1-pin 1x18/20W

6000/542- 9011-0130 / 114863

Light fitting for fluorescent lamps explosion -protected

Contact us for request