BRAND | Dynalco |
Product | SST2200A |
Description | Transducer with sensor |
Internal code | ONR4876297 |
Technical specification | Proportional outputs of either 4–20 mA (standard), 0–5 Vdc, or 0–10 Vdc are fieldselectable. Standard 0-1 mAdc meter output included Models available with up to four alarm setpoints Field-selectable frequency range Field-adjustable sensitivity control Field-programmable for many types of sensors, including contact closure input Repeater output drives counters and self-powered digital tachometers such as Dynalco's SPD-100 and SPD-700 Regulated 14 Vdc output powers active pickups (e.g. M910), accessories, and digital meters such as DPM-105 or MTH-103D, and the 12 Vdc versions of the internally lighted SPD-100L and LST-100L Alarms are field-configurable for DPDT (SST-2400 A or -H only), overspeed,underspeed, energize, de-energize, latch, auto-reset Integral VERIFY, requires external meter. Permits viewing and setting of setpoint value without actuating the relays Input Frequency: Full-scale values from 0–0.1Hz (6 pulses per minute) to 0–50,000 Hz Function: Converts frequency input (speed, rate) into linear proportional dc output. Provides alarm setpoints for over- and underspeed control and for sequential, startup, and shutdown switching Applications: Includes engines, machines, I/P drivers, instrumentation, process control, recording, measurement Signal Sources: Includes magnetic pickups, ac generators, contact closures, photocells Output Range Capability: Current source up to 50 mAdc output always included Alarm Setpoints: Available with two or four relays. Also available with no relays if only proportional outputs are required. |