BRAND | EAS Technischer Brandschutz GmbH |
Product | SECURUS 90-RKS-05 |
Description | Smoke switch coupling device |
Internal code | ONR4854108 |
Technical specification | Smoke switch coupling device for control cabinet installation Smoke switch coupling device in the SECURUS 90 safety system for Early smoke and fire detection in electrical control cabinets for connecting a maximum of 20 RSS-03 smoke switches. As a modular unit with simple, faster DIN rail mounting, (TS35) suitable for standard field sections Space required 9 TE. In the security system as a local device with only a small display and operating options. Display and operation are then carried out on a central control and display device (AWG evaluation device 05). 10 switching inputs and 7 switching outputs with standard programming. Realization of early fire detection through programmable Temperature and smoke concentration thresholds for Generate alerts and critical alerts. EAS bus interface based on CAN bus for implementation large system structures hardware • Infineon SAF XC164CS microcontroller 40MHz • 256 KB RAM • 4 status displays via the integrated LED: Green operation Yellow fault/communication Nication disorder Orange warning/critical warning Red alarm • 1 EAS bus interface with 50kbit/s, max. 1 km in length. Bus topology can be used with Bridges and repeaters are optimized. • Service interface: RS232 • 10 24V switching inputs: Acknowledge, suppress, freely definable inputs E3 — E7, power supply fault Gung, reset • 7 relay outputs 30V, 1A: alarm, malfunction, communication malfunction, Warning, critical warning, alarm for signalling, collective message inputs E3 — E7 firmware • Management of max. 20 smoke switches • 2 threshold values each for temperature and Smoke concentration and a threshold programmable for contamination • Message list with 64 entries • History with 1000 entries • Self-monitoring • Monitoring of transmission routes • Networking: up to 64 master/slave devices Start-up software • Start up the local device as Slave • VDS mode setting • Setting the MAC address on the EAS bus • Assignment of location code • System time setting • Starting up the connected smoke switch • Assignment of the location code of smoke switch • Setting the MAC address on the RS bus • Setting the thresholds for smoke concentration, temperature and soiling specifications • Quick direct installation on hat rails TS 35/9 TE • All connections via screw terminals 3.5 mm grid size, Wire cross section 0.75mm² FM or BM cable 0.8 mm • Operating voltage 18 to 28 V DC • Max. power consumption at 24V DC approx. 138 mA • Type Power consumption approx. 108 mA • Protection class IP 20 • Operating temperature -10°C to +70°C |
Press on flag images to see contact information!