productattachments_files_r_o_rotronic_catalogue_en_2020-v1_1.pdf |
Transmitters for humidity and temperature 2-wire operation, Power supply: 10 ... 28 VDC, Duct installation, Probe Dimensions: 208 x 15 mm, OUT1: 4 ... 20 mA = 0 ... 50 ° C.
Messumformer für Feuchte und Temperatur
Transmitter for temperature and dew point Channel version, 3/4-wire, 15 ... 40 VDC / 12 ... 28 VAC, vertical mounting, 1 M16x1.5 gland, Output signals: OUT1: 0 ... 20 mA = -40 ... 60 ° C, OUT2: 0 ... 20 mA = -50 ... 50 ° C (DP
Transmitters for humidity and temperature Channel version, 3/4-wire, vertical mounting, 15 ... 40 VDC / 12 ... 28 VAC, RS485 on terminals, 1 x M16 gland, Output signals: OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 100 ° C.
Messumformer für Feuchte und Temperatur
Transmitters for humidity and temperature Wall design, horizontal mounting, Included LCD display with operating panel, 15 ... 40 VDC / 12 ... 24 VAC, 4.3 wire that Output signals: OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 150 ° C.
transducer
transducer
transmitter, Power : 15 – 40 VDC / 12 - 28 VAC, OP.Range : -400… / + 60 oC, Out H : 0….100 % RH 4-20 mA, Out T : 0….+50oC 4-20 mA
Transmitters for humidity and temperature Channel model with 550 mm probe length, PPS trunk 15 mm, 3/4-wire version, IP65 aluminum die-cast housing, Power supply: 15 ... 40 VDC / 12 VAC ... 28, Connection: 1 M16x1.5 stainless steel nuts, Output signals: OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 50 ° C.
Messumformer
Transmitter for humidity and temperature channel design with 250 mm probe length, PPS trunk 25/15 mm, 3/4-wire version, IP65 die-cast aluminum casing, power supply 15 ... 40 VDC / 12 ... 28 VAC, connection: 7-pole plug tuchel, (+ supply signals), output signals OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 150 ° C.
Moisture meter
(Data logger for relative humidity and Temperature with display with integrated sensors, Display with backlight, Alarm via LED display, Battery status display, Function key: start / stop logging, Real-time function (RTC) Loop or start / stop storage mode, Measuring range: 0 ... 100% RH / 0 ... 50 ° C, Accuracy (23 ° C): ± 0.8% RH / ± 0.2 ° C, Repeatability: ± 0.3% RH / ± 0.05 ° C, Long term stability: <1% RH / 0.1 ° C / year, Calculations: dew or frost point, Log-interval: 5 seconds to 1 hour, Interface: UART to USB (via AC3006) Housing material: ABS, Dimensions: 130 x 72 x 32 mm, Weight: about 270 g).
Hand-held instrument with an integrated probe for humidity and temperature.
Handmessgeräte HygroPalm 22 für austauschbare HygroClip2-Fühler
Sensor module for humidity and temperature HC2-S; 1 calibration ER-15; 1 Humidity standard EA80-SCS; 1 extension cable E2-02A; 1 Service case AC1127
Hand-held instrument for 2 Sensor Module HC-2 or 2 analog sensor inputs (for 0.1 VDC or 0:20 mA), 9 V battery, calculating Absolufeuchtewerten, real-time clock with battery backup, Probe adjustment directly Taupunktreferenz, remote control ungsfunktion for transmitters, application range unit: 0 ... 100% rh / -10 ... 60 ° C measuring ranges depending sensor, mini USB interface Stores up to 16,000 readings: Each data sets contains humidity, temperature, date, time, batch number and user ID number ...
(Aw or% rh and ° C) hand-held instrument for quick AW measurement for humidity and temperature, calculation of all psychrometric humidity values, including internal memory for 20,000 records with real-time clock, data-capture function, mini-USB port (UART), Application : 0 ... 1 aw (0 ... 100% rh) / -10 ... 60 ° C, precision: sensor-dependent, automatic determination of the equilibrium state, including AW-qUICK-function for fast measurement of water activity.
Portable Water Activity System
humidity sensor
Industrial transmitter with instructions HygroFlex 1 12-35VDC / 24VAC, 2 analog outputs, 1 digital sensor input.
out 1:HO... 100%RH 4-20ma out 2:TO...100C 4-20ma
3 analog outputs, 1 digital output, RS232 interface, network compatible (RS485), optional 2nd sensor input connector 5-pole, 4 ... 20 mA = 0 ... 100% RH, 0 ... 100 ° C and calculated value, 1 x M16 cable glands Power supply: 12 ... 35 VDC / 12 ... 24 VAC
Insertion Probe - Barrel: 280mm x 10mm dia., 2m cable - Operating Range: -40…185ºF (-40…85ºC)