BRAND | Reco |
Product | RM-V16 ATEX |
Description | filter control unit |
Internal code | ONR4293603 |
Technical specification | RM-V16 ATEX Execution: - built into the plastic housing - Time or differential pressure controlled filter cleaning, with built-in adjustable timer for pulse and pause times - Control of 3 filter cleaning valves (on-site) - Voltage: 24 V DC - impulse operation - 2 analog inputs: 4 ... 20 mA; 0 ... 5000 Pa differential pressure sensors 4-wire and 2-wire technology - 3 digital inputs: 24 V DC, potential-free - 2 transistor outputs: 24 V DC - Input voltage: 24 V DC - Output voltage: 24 V DC Housing design: - Dimensions: 260x160x90 mm (LxWxH) ATEX version: - Zone: 2 Category 3G / 3D - Ex de IIB / IIIB T2 (300 ° C) - Type of protection for field devices: Ex II 2G / 2D Ex i IIC / IIIC T4 The control unit is mounted on the on-site housing and wired to the on-site valves. |