Labom

Sales Labom in United States

You can contact us if you wish to receive tender about Labom brand. Our company can provide optimal endustrial accessories supplies for you from overseas. Labom products, produce properly for customer's necessities, can bu used easily even if in the hardest situations. When you wish to receive tender, just let us know the information of model.

Brand products Labom

GA2520

THERMOMETER RESISTOR

GA2540-HY-A141066-C1299999-D2-M22-N2-T11-Z1-W4057-W1020 PA2250-F12

RESISTANCE THERMOMETER Pt100 for food / pharmaceutical / biotechnology

GA2700 1*PT1003-WIRE

Measurement And Control Devices RANGE: -50,,,200c 1*PT1003-WİRE

GA2700HY A1432 C1025 G11 N2

30Ra, 0-150C/24VDC - CofC Tube, 1/2"

GA2700-HY-A1011-C1000-G15-N2-T150

(Resistance thermometer MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 measuring resistor 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 11 nominal diameter: 1/2 B conical sealing C1000 temperature sensor: flush G15 material wetted parts: stainless steel material 1.4404 (316L) / PEEK FDA compliant N2 measuring insert: 1 x Pt 100 in 3-wire system, standard T150 electrical connection: circular connector M 12x1 (4-pole) using the range -50 ... + 200 ° C)

GA2700-HY-A1011-C1025-G11-N3-T150

[RESISTANCE THERMOMETER MiniTherm for Food / pharmaceutical / biotechnology Sheet according T4-015 RTD: 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 11 nominal diameter: 1/2 B conical sealing C1 Temperature sensor: ø 6 mm 025 Installation length U1: 25 mm G11 Material wetted parts: stainless steel mat 1.4404 (316L) N3 measuring insert: 1 x Pt 100 (bridged 3-wire) in 4-wire technology T150 electrical connection: Circular connector M 12x1 (4 poles) Range of -50 ... + 200 ° C]

GA2700-HY-A1031-C4025-G11-N2-T150-Z52 PA2430-F12-H1

(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 measuring resistor 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm tapered for a diameter of 4 mm 025 installation length U1: 25 mm G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100 in 3-wire, standard T150 electrical connection: circular connector M 12x1 (4 poles ) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430) PA243 transmitter for temperature (Pt 100), programmed according to data sheet T4-082-1 ​​electrical connection. round connector M12x1 (4-pole) 0 type: standard configuration F12: see below measuring range: 0 ... + 150 ° C leakage current with sensor break: 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)

GA2700-HY-A1031-C4030-G11-N2-T150-Z52 PA2430-F12-H1

(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm, tapered to ø 4 mm 030 installation length U1: 30 mm G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100 in 3-wire, standard T150 electrical connection: circular connector M 12x1 (4 poles) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430. ) PA243 TRANSMITTER (for temperature Pt 100), programmed according to data sheet T4-082-1 ​​electrical connection: circular connector M12x1 (4-pole) 0 Type: standard configuration F12: see below measurement range: 0 ... + 150 ° C leakage current with sensor break : 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)

GA2700-HY-A1031-C4990-G11-N2-T150-Z52 PA2430-F12-H1

(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 measuring resistor 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm tapered for a diameter of 4 mm 990 Einaulänge U1 (in mm): 20 G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100-3-wire system, standard T150 electrical connection: circular connector M 12x1 (4 poles) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430) PA243 transmitter for temperature (Pt 100), programmed according to data sheet T4-082-1 ​​electrical connection. round connector M12x1 (4-pole) 0 type: standard configuration F12 : see below measurement range: 0 ... + 150 ° C leakage current with sensor break: 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)

GA2720-A99-C4025-G11-N2-T150-Z52-W4035-W4020-W5422-W1020 PA2430-F12-H1

(RESISTANCE THERMOMETER MiniTherm for Food / pharmaceutical / biotechnology with separate thermowell Explosion protection: without welded thermowell according to drawing B4-CA-00019-z (PG-MB-00025-k))

GA9130-C201250-T11-Z1

Measuring range 0 ... 250 ° C

MANOMETER 0 ÷ 25 MPA; Ø100; M20H1 5: ACCURACY CLASS 1.6

1. Scope - 0 ÷ 250 kgf / cm 2. Accuracy class - 1.6 3. Diameter - Ø 100 4. Join-radially by thread M20x1.5

MANOMETER 0 ÷ 40 MPA;   Ø 100; M20XL, 5; ¬ CLASS 1.6 ACCURACY.

1. Scope -0 ÷ 400 kgs/sm2 2. Accuracy class - 1.6 3. Diameter-Ø 100 4. Join radial-threaded M20h1 5

MC1090

MULTIFUNCTION DISPLAY for PASCAL CV

MT8100-A1

(MT8 weld G 1/2 100 conically sealing, material stainless steel mat 1.4404 A1 without inspection hole)

PROD. NO: 1234/1/1

pascal cv supply 24 v dc

W1020

material inspection certificate

ВН5120 ECO-HY-A58-K137

PRESSURE GAUGE NG 63 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH51 20 Enclosure: IP 65 with case filling, process connection bottom HY surface roughness: according to the hygienic design A58 display range: 0 ... 10 bar Overload protection: 1.3 times Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C

ВН5210 ECO-HY-A57-K137

PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 10 Enclosure: IP 65 Process connection back HY surface roughness: according to the hygienic design A57 display range: 0 ... 6 bar Overload protection: 1.3 times Hands: with micro Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C

ВН5220 ECO-HY-A57-K137

PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 20 Enclosure: IP 65 with case filling, process connection bottom HY surface roughness: according to the hygienic design A57 display range: 0 ... 6 bar Overload protection: 1.3 times Hands: with micro Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C

ВН5220 ECO-HY-A90-K137

PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 20 Enclosure: IP 65 with case filling, process connection bottom HY surface roughness: according to the hygienic design A90 display range: -1 ... 5 bar Overload protection: 1.3 times Hands: with micro Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C

ВН5230 ECO-HY-A57-K137

PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 Enclosure: IP 65 with case filling, process connection on the back 30 HY surface roughness: according to the hygienic design A57 display range: 0 ... 6 bar Overload protection: 1.3 times Hands: with micro Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C

Contact us for request