Ime

Sales Ime in United States

Economize your outlays when recovering your machine in technical way thanks to Ime products. Products have modern technology rank as succesfully in many endustry deparments. Ime products, produce properly for customer's necessities, can bu used easily even if in the hardest situations. When you wish to receive tender, just let us know the information of model.

Brand products Ime

ADGIP544 

MASK FOR DISPLAY - 96X48

DER060D200

SHUNT FOR DC INSTRUMENT

DG4N2HN6

digital display

MF7FT40036 NEMO72-L

, Unbalanced load is 3- or 4-wire three-phase system Panel mounting; Front frame 72x72mm² Panel cut 68x68mm² LCD display; 4 lines; Character height 5mm Display of: voltage; Electricity; Power factor; Active, reactive and apparent power; Frequency; Active and reactive power; Mean power; Average current; Harmonic content (current) Input voltage: 80 ... 500V (phase-phase) Transformer ratio programmable Power Input: transformer connection 1A (CT secondary must not be grounded) Transformer ratio programmable Frequency: 47 ... 63Hz Output: RS485 communication Protocol: JBUS / MODBUS Accuracy: 0.5 Kl (I, U);. Kl 1.5 (P, Q, S). . Kl 2 (active energy); Kl. 3 (reactive energy) Programmable parameters: network type; Communication; Power and average power Supply voltage: 230V 63Hz 47 ...

MF7FT40046 NEMO72-L

Multifunction indicator Type: Nemo72-L , Unbalanced load is 3- or 4-wire three-phase system Panel mounting; Front frame 72x72mm² Panel cut 68x68mm² LCD display; 4 lines; Character height 5mm Display of: voltage; Electricity; Power factor; Active, reactive and apparent power; Frequency; Active and reactive power; Mean power; Average current; Harmonic content (current) Input voltage: 80 ... 500V (phase-phase) Transformer ratio programmable Power Input: transformer connection 5A (current transformer secondary must not be grounded) Transformer ratio programmable Frequency: 47 ... 63Hz Output: RS485 communication Protocol: JBUS / MODBUS Accuracy: 0.5 Kl (I, U);. Kl 1.5 (P, Q, S). . Kl 2 (active energy); Kl. 3 (reactive energy) Programmable parameters: network type; Communication; Power and average power Supply voltage: 230V 63Hz 47 ...

MF7FTU0036 NEMO72-L

Nemo72-L: Multifunction Display Type  , Unbalanced load is 3- or 4-wire three-phase system Panel mounting; Front frame 72x72mm² Panel cut 68x68mm² LCD display; 4 lines; Character height 5mm Display of: voltage; Electricity; Power factor; Active, reactive and apparent power; Frequency; Active and reactive power; Mean power; Average current; Harmonic content (current) Input voltage: 80 ... 500V (phase-phase) Transformer ratio programmable Power Input: transformer connection 5A (current transformer secondary must not be grounded) Transformer ratio programmable Frequency: 47 ... 63Hz Output: Pulse output for active energy Pulse duration prog. (50 ... 300ms) Pulse value prog. (1Imp / 10Wh ... 1Imp / 100kWh) Accuracy: 0.5 Kl (I, U);. Kl 1.5 (P, Q, S). . Kl 2 (active energy); Kl. 3 (reactive energy) Programmable parameters: network type; Pulse output; Power and average power Supply voltage: 230V 63Hz 47 ...

MF7FTU0046 NEMO72-L

Multifunction Display Type: Nemo72-L , Unbalanced load is 3- or 4-wire three-phase system Panel mounting; Front frame 72x72mm² Panel cut 68x68mm² LCD display; 4 lines; Character height 5mm Display of: voltage; Electricity; Power factor; Active, reactive and apparent power; Frequency; Active and reactive power; Mean power; Average current; Harmonic content (current) Input voltage: 80 ... 500V (phase-phase) Transformer ratio programmable Power Input: transformer connection 5A (current transformer secondary must not be grounded) Transformer ratio programmable Frequency: 47 ... 63Hz Output: Pulse output for active energy Pulse duration prog. (50 ... 300ms) Pulse value prog. (1Imp / 10Wh ... 1Imp / 100kWh) Accuracy: 0.5 Kl (I, U);. Kl 1.5 (P, Q, S). . Kl 2 (active energy); Kl. 3 (reactive energy) Programmable parameters: network type; Pulse output; Power and average power Supply voltage: 230V 63Hz 47 ...

TM4I330-2

Current Transducer

AN3212C100/ RQ96E

Analoganzeiger Wechselstrom für Wandleranschluss 100/1A

TM4U3102

Messumformer Wechselspannung True RMS

TM4I340-2

Messumformer Wechselstrom True RMS

TM3ULP0 0-130,9V

Messumformer Wechselspannung

TM3UL20

Messumformer Wechselspannung

TM3ULP0 0-139,9V

Messumformer Wechselspannung

ANTJ21

Synchronism Relay with LED to contact

AN3211C800 ( RQ96E)

Analog Ammeter

TA42650C160

CURRENT TRANSFORMER

ANTJ11

relay

ANTJ10 ( SYNCRO 96C )

LED synchroscope with synchronizing contact

ANTJ30 (Syncro 96C)

LED synchroscope with synchronizing contact

Contact us for request