BRAND | Vaisala |
Product | HMT360 3A12BCD2A4B15A10 |
Description | TEMPERATURE TRANSMITTER |
Internal code | ONR4271677 |
Technical specification | • Safe operation of the transmitter in harsh areas. • Intrinsic safety: you can install the complete transmitter in the area of explosion. • Vaisala HUMICAP® sensor offers high precision, excellent long-term stability term. • NIST certificate included. • Factory Mutual (USA). • 2 m cable for the probe. Humidity measurement Measuring range 0 ... 100% RH Precision At +15 ... +25 ° C (59 ... +77 ° F) ± 1.0% RH (0 ... 90% RH) ± 1.7% RH (90 ... 100% RH) At -20 ... +40 ° C (-4 ... +104 ° F) ± (1.0 + 0.008 x reading)% RH At -40 ... +180 ° C (-40 ... +356 ° F) ± (1.5 +0.015 x reading)% RH HUMICAP® 180R Sensor Temperature measurement Measuring range -20 ... +80 ° C (-4 ... +176 ° F) Accuracy + 20 ° C (+ 68 ° F) ± 0.2 ° C (0.36 ° F) Sensor Pt1000 RTD 1/3 Class B IEC 751 Inputs and outputs Operating voltage 12 ... 28 V Analog output 4 ... 20 mA x 2 Environmental operating conditions Probe Equal to measuring range Transmitter -20 ... +60 ° C (-4 ... 140 ° F) Mechanical characteristics Cable length from probe to transmitter 2 m Plastic grid filter with sintered steel mesh Probe material Stainless steel Transmitter Protection Degree IP66 (NEMA 4X) Housing material G-AlSi10Mg (DIN 1725) |