BRAND | Labom |
Product | GA2540-HY-A141066-C1221250-D2-M22-N2-T11 |
Description | resistance thermometer |
Internal code | ONR4432177 |
Custom code | 90251900 |
Technical specification | GA254 RESISTANCE THERMOMETER Pt 100 for food/pharmaceuticals/biotechnology see data sheet T4-024 0 explosion protection: without hygienic design: surface roughness (wetted parts) - turned parts Ra <= 0.8 μm - welding Ra <= 1.5 μm HY A1410 process connection: clamp connection per DIN 32676 66 nominal width: DN 25 C12 thermowell ø: F1 = 9 mm 2 material thermowell: stainless steel mat.-no. 1.4404 (316L) 1 neck tube: M = 80 mm 250 immersion length U1: 250 mm length of measuring insert l5: 340 mm D2 measuring insert: ø 6 mm, rigid M2 accuracy: class A per DIN EN 60751 2 application range: -50...+400°C, standard N2 sensor type: 1 x Pt100, 3-wire technology connection head: model B, cap with 2 slotted screws, mat: aluminium, IP 54 T11 electrical connection: M20x1.5 cable gland for cable ø 9-14 mm, material nickel-plated brass |
Press on flag images to see contact information!