BRAND | KRS KUEBLER |
Product | FFG-BP.20H3O N- UTK48-2430 |
Internal code | ONR4959934 |
Custom code | 90261029 |
Technical specification | Bypass mount magnetostrictive sensor type BLM-SAD Approval: ATEX - Ex d; ZELM 13 ATEX 0508 X II 2G Ex d IIB T3 up to T6Gb Standard (-10°C to 185°C) (media temperature) Ambient temperature: -40°C... +85°C Case material: IP67 stainless steel LCD display: Without Electrical connection: M20x1.5 mm cable screw Output signal: 4-20 mA - HART Ver. 7 Case arrangement: angled upwards - housing at 9 o'clock/270° Sliding tube: Ø 12 mm Measurement range: 2430 mm Tube length: 2580 mm Weight: 2.2 kg Permissible temperatures for the bypass mount sensor (BLM) :Allowable surface temperature of the pipe and ambient temperature of the For housing, see note in MuB Acceptance test certificate 3.1 in accordance with EN 10204 Certificate type: Acceptance test certificate DIN EN 10204 3.1 Certificate language: English and German Certificate/testimony for: Bypass level transmitter Measurement accuracy: List of individual measurement values (with 5 measurement points) |