BRAND | Labom |
Product | CV3110-A1051-F10-H1100-M1-N10-T20-K1085-K80 |
Description | Pressure Transmitters |
Internal code | ONR4195514 |
Custom code | 90262020 |
Technical specification | CV3110 PASCAL CV, for pressure sediter mounting, hygienic according to data sheet D4-017-22 A1 pressure sensor: piezoresistive for overpressure 051 Nominal range: 0... 0.4 bar, overload limit 1 bar Range adjustment: Turndown 5:1 Accuracy: <= 0.15% of the set range (Lin. /Hys. /Rep.), default F10 Range: 0... 0.4000 bar H11 output signal: 4... 20 mA, characteristic curve rising 0 damping: 0.0 sec standard 0 Setting Alert: < 3.6 mA, Standard M1 display module: without Screw cap: closed, without viewing panel N10 Switching module: without Housing: hygienic housing design with screw cap Material: Stainless steel Housing protection rating: IP 66 T20 electrical connection: Cable gland M16x1.5 PA black K1085 Type: Standard K80 process connection: G1 A/PN10-50 with hygienic elastomer-free waterproofing Process temperature: 0... +125 °C, briefly up to +140 °C, 1 h |