BRAND | Labom |
Product | CC6020-B1111-H2-T310 DL2100-HY-A4007-L22 |
Internal code | ONR4960687 |
Custom code | 90262020 |
Technical specification | CC6 PRESSURE TRANSMITTER COMPACT for diaphragm seal operation 02 design: with temperature decoupler see data sheet D4-020-7 0 explosion protection: without B1 pressure sensor piezoresistive for absolute pressure 111 measuring range 1...11 bar abs., overload limit 60 bar measuring accuracy: linearity error incl. hysteresis < + 0.2 % f.s. accuracy of adjustment < +/- 0.2 % f.s. H2 output signal: 0...20 mA, 3-wire technology T31 electrical connection: cable connection IP 67, union nut of polyamide 0 2 m cable length DL DIAPHRAGM SEAL for food / pharmaceutical / biotechnology 2 design with coupling nut -see data sheet D5-025 100 process connection: DIN 11851, DN 25 / PN 40 HY hygienic design per EHEDG Doc.8 and ASME BPE SF3 surface roughness (wetted parts) - turned parts Ra <= 0.76 μm - diaphragm Ra <= 0.38 μm - weld seam Ra <= 0.76 μm A400 connection of meas. instrument directly welded 7 material wetted parts: stainless steel mat.-no. 1.4435 (316L) L22 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered design temperature process -10...+140 °C |
Press on flag images to see contact information!