BRAND | Labom |
Product | CC6010-A1058-H1-T905-W2002 |
Description | sensor |
Internal code | ONR4278988 |
Custom code | 90262020 |
Technical specification | DL4100-HY06-A4007.7-L23-T99-W1020 CC6 PRESSURE TRANSMITTER COMPACT for diaphragm seal operation 01 design: standard see data sheet D4-020-5 0 explosion protection: without A1 pressure sensor piezoresistive for gauge pressure 058 measuring range 0...10 bar, overload limit 60 bar measuring accuracy: linearity error incl. hysteresis < + 0.2 % f.s. accuracy of adjustment < +/- 0.2 % f.s. H1 output signal: 4...20 mA, 2-wire technology T905 electrical connection: circular connector M12 with twist lock, IP 65, union nut of stainless steel W2002 CALIBRATION PROTOCOL: with 5 measuring points DL DIAPHRAGM SEAL for food / pharmaceutical / biotechnology 4 design with clamp connection see data sheet D5-026 100 process connection: per DIN 32676 model A (metric) for pipes per EN 10357, DN 25 / PN 25 HY06 hygienic design per EHEDG Doc.8 and ASME BPE SF1: surface roughness (wetted parts) - turned parts Ra <= 0.51 μm - diaphragm Ra <= 0.38 μm - weld seam Ra <= 0.76 μm A400 connection of meas. instrument directly welded 7.7 material wetted parts: st. steel mat.-no. 1.4435 (316L), delta ferrite content < 1 % L23 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered DMB_1318 T99 temperature, media: see below +10...+130°C W1020 Components marked acc. to material inspection certificate per EN 10204-3.1, wetted parts |
Press on flag images to see contact information!