Register with pulse output, Electronic counter LCR type with an LCD display and, pulse output above for OG-Baureihe.Anzeige 1: resettable totalizer or flow indication programmable, Format xxxx.x. Display 2: Non-resettable totalizer, 14 digits. Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA Protection: IP 64 For counter Size: M25-M35-M40-M70-M120-M170 Pulse output: NPN, MOSFET 40V / 2A Pulse factor: 0.01-99.99 Pulse length: 10ms (2ms, 20ms, 40ms) Ext.Stromversorg. : 8-24VDC Pulse output PPL: 0,01-0,1-1-10-100 Dosing control: 0.01 to 999.99 Preliminary circuit: from 0.00 to 99.99 Switching output: NPN, MOSFET 40V / 2A
Electronic counter LCR type with an LCD display, Display 1: resettable totalizer or Flow display programmable, Format xxx.xx. Display 2: Non-resettable totalizer 14 digits. Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA
Electronic counter LCR type with an LCD display, for the OG series Display 1: resettable totalizer or Flow display programmable, format xxxx.x Display 2: Non-resettable totalizer 14 digits Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA Protection: IP 64
3/4 "or 1" PPO Viton without pulse, fluid meter RCDL M25 without construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, standing
Vectra Viton pulse PFT-2 reed contact Liquid meter RCDL M25 without construction. Materials and technical data: Housing: Bronze Measuring chamber: Vectra O-rings: Viton Measuring range: 3-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: ° C Connection: R 1 "outside Installation length: 190 mm Installation position: horizontal, standing 604011 Pulse PFT-2 reed contact about 52 PPL
liquid meter
(Liquid meter RCDL M25 without Construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, vertical)
Housing : Bronze Chamber : Noryl (PPO) O-Rings : Buna Flowrange : 1-100 l/min Accuracy : +/- 1,5 % of value p-max : 10 bar t-max : 50 °C Connection : Threads 1" male Laylength : 190mm Pulsoutput : Open Collector NPN Scale Factor : 0.00001 to 0.9999 Supply : 12-24 VDC Pulsoutput : S/N : Part-Nr. 141158
MID M 2000 mit Flansch DN 50 1.4571
Oval wheel counter
magnetic inductive flowmeter
Electromagnetic Flow Meter
Pulse Flow meter
Magnetisch-Induktiver-Durchflußmesser
Magnetisch-Induktiver-Durchflußmesser
Elektronischer Vorwahlzähler
flowmeter for diesel
Impulsgeber
Signal Transmitters
flowmeter
magnetic flow meter
Card