BRAND | Inor |
Product | APAQ-C130 |
Description | Digital temperature transmitter for head mounting |
Internal code | ONR4684627 |
Custom code | 90303320 |
Technical specification | 70C1300211 for thermocouples Input: thermocouples types B, E, J, K, N, R, S and T; output: 4... 20 mA, galvanically not separated; Measurement range: see data sheet; Sensor error: In accordance with NAMUR NE43; Zero point: Any value in the measurement range; Min. measurement range: see data sheet; Ambient temperature: -40... 85°C/-40... 185 °F; Vibration: In accordance with IEC 60068-2-6.10 g; EMC: EN 61326-1/EN 61326-2-3; Typical accuracy (for type K): max. ±1 K or ± 0.2% of MB: Long-term stability: max. drift ± 0.05% over a range/year; Adjustable filter: 0.4 to 26 s; Power supply: 6... 32 VDC; configuration: Using the “INOR Connect” app*; Wireless connectivity: NFC® interface; |
Press on flag images to see contact information!