BRAND | Labom |
Product | CC6010-A1090.1-H1-T110 DF3210-HY-F2-A4007-L22 |
Internal code | ONR4890435 |
Technical specification | Spare part for Fab.-No.: 2104163/10/001 cc6 PRESSURE TRANSMITTER COMPACT for diaphragm seal operation 01 design: standard see data sheet D4-020-5 0 explosion protection: without A1 pressure sensor piezoresistive for gauge pressure 090.1 measuring range -1...5 bar, overload limit 60 bar measuring accuracy linearity error incl. hysteresis < + 0.2 % f.s. accuracy of adjustment <+/-0.2 % f. H1 output signal: 4..20 mA, 2-wire technology T110 electrical connection right angle plug acc. to DIN EN 175301-803-A (DIN 43650, model A) IP 65, for cable @ 4..10 mm DF INLINE DIAPHRAGM SEAL for food / pharmaceuticals / biotechnology see data sheet D5-064 32 process connection: for pipes per BS 4825 Part 3 and O.D. Tube (suitable for pipes per ASME-BPE 1997) clamp connection on both sides per ISO 2852 10 nominal width: pipe DN 1", pipe inside-o 22.2 mm clamp connection DN 25/ PN 16, outside- 50.5 mm HY hygienic design per EHEDG Doc.8 and ASME BPE SF3 surface roughness (wetted parts) - tumed parts Ra <= 0.76 ym - diaphragm Ra <= 0.38 ym - weld seam Ra <= 0.76 ym F2 insertion length L: 110 mm A400 connection of meas. instrument directly welded 7 material wetted parts: diaphragm st. steel mat.no. 1.4435 (316L), basic body st. steel mat-no. 14404 (316L) L22 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / Hi-registered operating temperature range -10...+140 °C DMB_4656 |
Press on flag images to see contact information!